What We Do?

Fiber Reinforced Concrete Delivered Across Georgia

Fiber reinforced concrete is ordinary ready mix with fibers blended through it at the plant. The fibers are distributed evenly across the whole load rather than sitting in one plane, and their job is to control the cracking that happens while a slab is still curing.

Southern Readymix supplies both synthetic and steel fiber, sourced from Euclid Chemical and Fiber Force. Dosage is specified to the job in pounds per cubic yard rather than run at a single fixed rate, so tell dispatch what you are pouring or read us the line from your plans and we will set it accordingly.

This page explains what fiber reinforced concrete does, where it helps most, and how to order it correctly for your pour.

Synthetic and Steel Fiber

We supply both synthetic and steel fiber reinforced concrete. Synthetic is the usual choice for crack control; steel adds toughness and post-crack load transfer.

Euclid and Fiber Force

Our fiber comes from Euclid Chemical and Fiber Force, both long-established names in concrete fiber reinforcement.

Dosage Specified Per Job

Dosage is set to the job in pounds per cubic yard rather than run at one fixed rate. Tell us the application or read us the spec.

Recommended for Slabs

Slabs are where we most often recommend fiber reinforced concrete: garage floors, basement slabs, patios, driveways and commercial flatwork.

What Fiber Does

How Fiber Reinforced Concrete Controls Shrinkage Cracking

Concrete shrinks as it gives up water, and in the first hours after placing it has almost no tensile strength to resist that shrinkage. The result is plastic shrinkage cracking: the fine, random surface cracks that appear on a slab within a day of the pour.

Fibers work in exactly that window. Millions of them are dispersed through the paste, so as the slab shrinks there is something in tension everywhere, not just where a sheet of mesh happens to lie. The cracking that does occur is finer and better distributed instead of concentrating into a few visible lines.

What fiber does not do is replace structural reinforcement. Where an engineer has designed rebar to carry load, that rebar is still required. Fiber and rebar solve different problems and are routinely used together.

That early window is exactly where fiber reinforced concrete earns its place, because the fibers are already in the mix before the first crack can form.

Fiber, Mesh and Rebar

How Fiber Compares to Wire Mesh and Rebar

Welded wire mesh has one persistent practical problem: it only works if it stays in the middle third of the slab, and on a real pour it frequently does not. Mesh gets walked down during placing, and once it is lying on the subgrade it contributes very little.

Fiber removes that failure mode. There is nothing to position, nothing to lift, and nothing to walk down. It is already through the mix when the truck arrives, and it is present at the surface where plastic shrinkage cracking actually starts, which is the one place mesh never reaches.

Synthetic and steel fiber do different jobs. Synthetic fiber is aimed at early-age shrinkage cracking and does not replace structural steel. Steel fiber is a different proposition: at engineered dosages it adds real toughness and carries load across a crack once one has formed, which is why it turns up in industrial floors and slabs designed around it.

Neither is a decision for the batch plant to make on your behalf. If your plans call for rebar, fiber goes in alongside it unless the engineer has designed otherwise. Where mesh was specified purely for crack control rather than structural capacity, fiber is often the more reliable choice — but confirm that with whoever engineered the slab.

Where mesh was specified only for crack control, fiber reinforced concrete is usually the more reliable choice, but the engineer who designed the slab should make that call.

Where It Fits

Where Fiber Reinforced Concrete Fits Best

Slabs are where we most often recommend it. Garage floors, basement slabs, patios, porches, driveways and commercial flatwork all share the same exposure: a large surface area, a lot of water leaving the top face early, and very little tensile strength in the first hours to resist the shrinkage that follows. That is precisely the window fiber works in.

The case is strongest on pours that are large in area relative to their thickness, and on anything placed in conditions that dry the surface quickly — wind, direct sun, low humidity, or a hot afternoon. Those are the pours that craze and check, and the ones where a customer notices the difference a week later.

Synthetic fiber covers the great majority of that residential and light commercial work. Steel fiber belongs on heavier duty flatwork — industrial floors, warehouse slabs and jointless or lightly jointed designs — where an engineer has specified it for toughness rather than for crack control alone.

Fiber is worth less on deep, heavily reinforced structural sections where surface area is small and rebar is doing the work, and it is not a substitute for proper curing. It reduces plastic shrinkage cracking; it does not excuse a slab that was never covered or kept damp. Finishers new to it sometimes ask about surface fibers: a small amount can show immediately after finishing, it does not affect the slab, and it wears away with use and weather.

Slabs are the natural home for fiber reinforced concrete, and the benefit grows with surface area and with anything that dries the top face quickly.

Where Quality Meets Consistency

Ordering Fiber Reinforced Concrete in Georgia

Order it as you would any mix: volume in cubic yards, strength in psi, slump, and a note that you want fiber. Tell dispatch whether you need synthetic or steel, and either describe the application or read us the specification — dosage is set to the job in pounds per cubic yard, not run at one fixed rate for every load. Our fiber comes from Euclid Chemical and Fiber Force.

Most fiber loads go out at 3000 psi around a four inch slump, which suits residential slabs and drives. Fiber can stiffen a mix slightly, so if the pour needs to move more freely, ask about a water reducer rather than adding water on site.

For pours under seven cubic yards, see short load concrete delivery. Use the concrete calculator to size the order.

Fiber mixes are batched at all eight Georgia plants: Locust Grove, Hampton, Jackson, Covington, Madison, Zebulon, Luthersville and Auburn. Call 770-914-9700 or use the contact form, and see the plant locations page for the plant nearest your job.

Our fiber comes from Euclid Chemical, a long-established manufacturer of concrete fibers and admixtures, alongside Fiber Force. If you need product data for a submittal on fiber reinforced concrete, ask dispatch and we will get it to you.

Order fiber reinforced concrete the same way you order any load, and tell us the application so the dosage is set correctly for the job.

Every one of our eight plants can batch fiber reinforced concrete, so the mix is available wherever your job sits in the trade area.